PRODUCTS
NF F 63-827 Rolling Stock Cables
- FIREROL High Temperature Single Core Unsheathed Cables 3000V
NF F 63-827 (FRF-HT-3SU)
Application :
- These cables are used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor, suitable for use in control, auxiliary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction :
-
Conductors Stranded tinned copper wires to IEC 60228 Class 5. Separator Polyester tape. Insulation Halogen free silicone rubber. -
NF F 63-827
NF F 16-101A. Conductor B. Insulation -
Nominal Voltage 3000V Maximum Conductor Temperature 120°C/140°C Temperature Range -40°C~+135°C Bending Radius 4 × Overall Diameter
Standards :
Electrical & Mechanical Properties :
Fire Performance in General :
-
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission EN 50267-2-1; IEC 60754-1; NF C 32-074;
NF C 20-454; VDE 0472 Teil 815Halogen Free EN 50267-2-2/3; IEC 60754-2; NF C 32-074;
NF C 20-453; VDE 0472 Teil 813
Low Corrosivity (Acidity & Conductivity) EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity NF F 63 808; BS6853; NF F 16 101 Smoke index EN45545-2 Requirement for fire behavior of materials & components R15/R16
FRF-HT-3SU 3000V :
-
Nominal Cross
Sectional AreaNumber & Nominal
Diameter of StrandsNominal Insulation
ThicknessOverall Diameter Weight Min. Max. mm2 No/mm mm mm mm kg/km 2.5 50/0.25 2.3 6.4 7.2 65 4.0 56/0.30 2.3 7.0 7.8 85 6.0 84/0.30 2.3 7.5 8.3 108 10.0 80/0.40 2.3 8.4 9.5 160 16.0 126/0.40 2.3 9.7 10.8 230 25.0 196/0.40 2.3 11.0 12.2 310 35.0 276/0.40 2.4 12.2 13.5 420 50.0 396/0.40 2.5 14.2 15.5 580 70.0 360/0.50 2.7 16.1 17.7 790 95.0 475/0.50 2.7 18.0 19.8 1030 120.0 608/0.50 2.8 20.0 21.9 1250 150.0 756/0.50 2.8 21.8 23.8 1560 185.0 925/0.50 2.9 23.7 25.9 1880 240.0 1221/0.50 3.1 26.6 29.1 2420
Impact Resistant |
Highly Flexible |
UV Resistant |
Ozone Resistant | Abrasion Retardant |
Cold- resistant |
Resistance To Soldering Heat |
Acid&Alkaline Resistant |
IRM 903 Fuel Oil Resistant |
IRM 902 Mineral Oil Resistant |
Fire Retardant NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4 |
Flame Retardant NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1 |
Low Toxicity NF X70-100/NF F63 808 TM1-04/BS 6853 |
Low Corrosivity IEC60754-2/EN50267-2-2/3 NF C32-074/VDE 0472-813 |
Low Smoke Emission IEC 61034-2 / EN 50268-2 NF C32-073/VDE 0472-816 |
Zero Halogen IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815 |